Length:
426 mm (16.8 in.)
Width:
483 mm (19.1 in.)
Height:
146 mm (5.8 in.)
Weight:
8 kg (17.7 lbs.)
Addressing and status:
Via P3 System Controller
Mapping:
Via P3 System Controller
Firmware update:
Via P3 System Controller
Device status:
Multicolor status LED
Power output status:
Four LEDs
Data output status:
Four LEDs
Device test and reset:
Pushbutton to call up local test patterns and reset device
Status LEDs and pushbutton can be disabled remotely if required.
Signal type:
Gigabit Ethernet
Protocol :
Proprietary Martin P3
Hot pluggable:
Yes, electrically isolated at all connections
Cable type:
Ethernet, CAT 5e or better
Cable length:
Up to 100 m (328 ft.) between any 2 devices, extendable with Ethernet switch or conversion to fiber
VDO Sceptron™ family
VDO Fatron™ family
VDO Dotron™ family
Exterior PixLine™ family
Exterior Dot-HP™ family
VC-Grid™ family (indoor product)
VC-Strip™ family (indoor product)
VC-Dot™ family via VC-Feeder™
Housing:
Aluminum
Color:
Alu grey (customized colors available on project basis)
Protection rating:
IP66
NEMA enclosure rating:
Type 3
Effective Projected Area (EPA):
0.21 m2
Corrosion resistance:
C5-M (very high corrosivity / marine, ISO 12944)
RoHS compliant
Mounting:
Brackets for installation on flat surface
Orientation:
Any, except with cable glands facing up or lid facing down
Power input:
Cable gland (M20), internal screw terminals
P3 data in/out:
Two cable glands (M16), two internal RJ45 connectors (if copper-to-fiber unit is installed, one cable gland can be used for fiber)
M16 cable glands accept 5.5 - 10 mm cable, M20 glands accept 8-13 mm cable.
Combined power & data out:
Four cable glands (M16), internal screw terminals
AC power:
120-277 V nominal, 50/60 Hz
Power supply unit:
Auto-ranging electronic switch-mode
Typical total power consumption:
1000 W (including full load of connected display devices, all at full intensity)
Typical half-cycle RMS inrush current:
20.9 A
Total power consumption in idle state (at 25° C, all connected devices powered off):
22 W
Cooling:
Convection
Total heat dissipation (calculated, +/- 10%):
345 BTU/hr. (not including display devices but with system at full load)
Maximum ambient temperature (Ta max.):
55° C
Minimum ambient temperature (Ta min.):
-30° C
EU safety:
EN 60950
EU EMC:
EN 55032, EN 55103-2, EN 55022, EN 55024, EN 61000-3-2, EN 61000-3-3
US safety:
ANSI/UL 60950-1
Canadian safety:
CSA C22.2 No. 60950-1
Cable glands
Martin P3-PC™ System Controller:
Free download from martin.com
P3-050 System Controller:
P/N 90721090
P3-100 System Controller:
P/N 90721010
P3-150 System Controller:
P/N 90721015
P3-200 System Controller:
P/N 90721020
P3-300 System Controller:
P/N 90721060
Martin P3 PowerPort™ 1000 IP, Installation Model:
P/N 90721080